CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (6.1)0.56%—Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+228/1/202217/6/2026
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web…
ModificadaAlta (8.6)0.82%—Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+228/1/202217/6/2026
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8…
ModificadaCrítica (9.8)1.1%—Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+228/1/202217/6/2026
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All…
ModificadaMedia (4.3)0.65%—Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+228/1/202217/6/2026
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8…
ModificadaAlta (7.5)1.0%—Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+228/1/202217/6/2026
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink…
ModificadaAlta (7.5)0.95%—Schneider-electric Scadapack 312e FirmwareSchneider-electric Scadapack 313e FirmwareSchneider-electric Scadapack 314e FirmwareSchneider-electric Scadapack 330e Firmware+528/1/202217/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E…
ModificadaMedia (5.3)0.77%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J,…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2…
ModificadaMedia (6.1)0.75%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase…
ModificadaMedia (5.5)0.65%—Schneider-electric Guicon28/1/202217/6/2026
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
ModificadaAlta (7.8)0.85%—Schneider-electric Guicon28/1/202217/6/2026
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
ModificadaAlta (7.8)0.81%—Schneider-electric Guicon28/1/202217/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
ModificadaBaja (3.8)0.24%—Schneider-electric Software Update28/1/202217/6/2026
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
ModificadaAlta (8.8)0.47%—Schneider-electric Evc1s22p4 FirmwareSchneider-electric Evc1s7p4 FirmwareSchneider-electric Evw2 FirmwareSchneider-electric Evf2 Firmware+228/1/202217/6/2026
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All…
ModificadaAlta (8.8)0.47%—Schneider-electric Evc1s22p4 FirmwareSchneider-electric Evc1s7p4 FirmwareSchneider-electric Evw2 FirmwareSchneider-electric Evf2 Firmware+228/1/202217/6/2026
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All…
ModificadaAlta (7.2)0.96%—Schneider-electric Accusine Pcsp Pfvp FirmwareSchneider-electric Accusine Pcsn Active Harmonic Filter Firmware2/9/202117/6/2026
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
ModificadaAlta (7.5)0.94%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all…
ModificadaAlta (7.8)0.33%—Schneider-electric Gp-pro EX2/9/202117/6/2026
A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software.
ModificadaCrítica (9.1)1.3%—Schneider-electric Vijeo DesignerSchneider-electric Ecostruxure Machine Expert2/9/202117/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of…