CVE-2021-22793
Estado: ModificadaAlta (7.2)—
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.96%
- Percentil entre todas las CVEs puntuadas: 60
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22793",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)",
"versions": [
{
"status": "affected",
"version": "AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)"
}
]
}
]
}
],
"published": "2021-09-02T17:15:08.393",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01",
"tags": [
"Not Applicable"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "nvd@nist.gov"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01",
"tags": [
"Not Applicable"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol."
},
{
"lang": "es",
"value": "Una CWE-200: Una vulnerabilidad de Exposición de Información Confidencial a un Actor no Autorizado en AccuSine PCS+ / PFV+ (versiones anteriores a V1.6.7) y AccuSine PCSn (versiones anteriores a V2.2.4) que podría permitir a un atacante autenticado acceder al dispositivo por medio del protocolo FTP"
}
],
"lastModified": "2026-06-17T03:37:47.863",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:accusine_pcsp_pfvp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "983C00E2-0BEF-484B-9D03-B87DE6CD77C1",
"versionEndExcluding": "001.006.007"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:accusine_pcs\\+:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3C31460D-46C2-4F3E-8DDB-98816B74EFB1"
},
{
"criteria": "cpe:2.3:h:schneider-electric:accusine_pfv\\+:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E3904B69-F4E3-4D69-A3C9-1F5201455745"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:accusine_pcsn_active_harmonic_filter_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1D69A10A-19FE-4485-AD03-7F3506D2D0E5",
"versionEndExcluding": "002.002.004"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:accusine_pcsn:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5FEFEF03-5CD7-498F-A538-928AA1D62F45"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}