| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.9) | 3.7% | — | Siemens Simatic Pcs7Siemens Simatic Wincc | 6/11/2017 | 17/6/2026 | An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash… | |
| Modificada | Alta (8.2) | 2.9% | — | Siemens Simatic Pcs7Siemens WinccOcpfoundation Local Discovery ServerOcpfoundation UA .net | 30/8/2017 | 17/6/2026 | An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All… | |
| Modificada | Media (6.4) | 0.38% | — | Siemens Primary Setup ToolSiemens Security Configuration ToolSiemens Simatic IT Production SuiteSiemens Simatic NET PC Software+14 | 15/11/2016 | 17/6/2026 | A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7… | |
| Modificada | Media (5) | 2.0% | — | Siemens Simatic PCS 7Siemens Simatic Pcs7Siemens Simatic TiaportalSiemens Simatic Wincc | 26/11/2014 | 17/6/2026 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. | |
| Modificada | Alta (10) | 5.3% | — | Siemens Simatic PCS 7Siemens Simatic Pcs7Siemens Simatic TiaportalSiemens Simatic Wincc | 26/11/2014 | 17/6/2026 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. | |
| Modificada | Media (6.8) | 1.1% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of… | |
| Modificada | Media (4.6) | 0.36% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. | |
| Modificada | Media (6) | 1.3% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. | |
| Modificada | Media (4.9) | 1.2% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | |
| Modificada | Media (5) | 1.7% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. | |
| Modificada | Media (4) | 1.3% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. | |
| Modificada | Alta (7.5) | 1.9% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. | |
| Modificada | Alta (7.5) | 1.8% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. | |
| Modificada | Media (4) | 2.3% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname. | |
| Modificada | Media (4) | 1.5% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query. | |
| Modificada | Media (5.8) | 1.9% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file. | |
| Modificada | Media (4) | 1.5% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query. | |
| Modificada | Media (6.1) | 1.0% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet. | |
| Modificada | Media (6.8) | 3.4% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter. | |
| Modificada | Media (4.3) | 2.2% | — | Siemens Simatic Pcs7Siemens Wincc | 18/9/2012 | 16/6/2026 | WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. | |
| Modificada | Alta (7.5) | 2.4% | — | Siemens Simatic Pcs7Siemens Wincc | 18/9/2012 | 16/6/2026 | SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message. | |
| Modificada | Media (4.3) | 2.1% | — | Siemens Simatic Pcs7Siemens Wincc | 18/9/2012 | 16/6/2026 | Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. | |
| Modificada | Media (5) | 2.6% | — | Siemens Simatic Pcs7Siemens Wincc | 18/9/2012 | 16/6/2026 | WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. | |
| Modificada | Media (6.8) | 0.98% | — | Siemens Simatic Pcs7Siemens Wincc | 18/9/2012 | 16/6/2026 | Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. | |
| Modificada | Media (6.9) | 0.46% | — | Siemens Simatic Pcs7Siemens Simatic Step 7 | 26/7/2012 | 16/6/2026 | Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder. |