Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2768▼ 554 respecto a la semana anterior
Críticas / altas1325▼ 178 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)268▼ 242 respecto a la semana anterior
–

16 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
AnalizadaAlta (8.1)0.32%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp341000h FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 Firmware+4214/2/202417/6/2026
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
ModificadaAlta (7.5)0.63%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+371/2/202317/6/2026
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP*…
ModificadaCrítica (9.8)1.5%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3331/1/202317/6/2026
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU…
ModificadaCrítica (9.8)1.2%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+5130/1/202317/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions),…
ModificadaAlta (7.5)0.75%—Schneider-electric Modicon M340 BMX P34-2010 FirmwareSchneider-electric Modicon M340 BMX P34-2030 FirmwareSchneider-electric Modicon M580 Bmeh582040 FirmwareSchneider-electric Modicon M580 Bmeh582040c Firmware+4422/11/202217/6/2026
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and…
ModificadaCrítica (9.8)0.77%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3212/9/202217/6/2026
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control…
ModificadaAlta (7.5)0.94%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all…
ModificadaCrítica (9.1)1.0%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric RemoteconnectSchneider-electric Modicon M580 Bmep581020 Firmware+2814/7/202117/6/2026
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70…
ModificadaAlta (7.5)1.3%—Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+1211/12/202017/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over…
ModificadaAlta (7.5)1.3%—Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+1611/12/202017/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over…
ModificadaAlta (7.5)1.4%—Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+1511/12/202017/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over…
ModificadaAlta (7.3)0.95%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Unity PROSchneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmeh584040 Firmware+196/1/202017/6/2026
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control…
ModificadaAlta (7.5)1.1%—Schneider-electric Bmenoc0301 FirmwareSchneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Bmeh586040 Firmware+915/7/201917/6/2026
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a…