| CVE | Status | Severity | EPSS | Active exploitation | Affected technologies | Published ▼ | Modified | Description |
|---|---|---|---|---|---|---|---|---|
| Modified | High (7.5) | 1.5% | — | Siemens DK Standard Ethernet ControllerSiemens Profinet DriverSiemens Simatic IPC SupportSiemens Ek-ertec 200 Firmware+48 | 2/11/2020 | 6/17/2026 | Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack.… | |
| Modified | High (7.5) | 2.1% | — | Siemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 FirmwareSiemens Ek-ertec 200p FirmwareSiemens Simatic CFU PA Firmware+62 | 10/10/2019 | 6/17/2026 | Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. | |
| Modified | High (7.5) | 1.4% | — | Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 Firmware+36 | 10/10/2019 | 6/17/2026 | An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. | |
| Modified | High (8.7) | 3.3% | — | Siemens Simatic S7-200 FirmwareSiemens Simatic S7-400pn V6 FirmwareSiemens Simatic S7-400h V6 FirmwareSiemens Simatic S7-400pn/dp V7 Firmware+34 | 12/26/2017 | 6/17/2026 | Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. | |
| Modified | High (7.1) | 0.91% | — | Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+75 | 5/11/2017 | 6/17/2026 | Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. | |
| Modified | High (7.1) | 1.1% | — | Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+89 | 5/11/2017 | 6/17/2026 | Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. | |
| Modified | Critical (9.8) | 34% | Exploit | Brother MFC FirmwareBrother DCP FirmwareBrother ADS FirmwareBrother HL Firmware | 4/12/2017 | 6/17/2026 | On certain Brother devices, authorization is mishandled by including a valid AuthCookie cookie in the HTTP response to a failed login attempt. Affected models are: MFC-J6973CDW MFC-J4420DW MFC-8710DW MFC-J4620DW MFC-L8850CDW MFC-J3720 MFC-J6520DW MFC-L2740DW MFC-J5910DW MFC-J6920DW MFC-L2700DW MFC-9130CW MFC-9330CDW… |