Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2568▼ 331 respecto a la semana anterior
Críticas / altas1352▲ 94 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 7 respecto a la semana anterior
Sin puntuar (sin CVSS)56▼ 472 respecto a la semana anterior
–

10 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (5.5)0.44%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user…
ModificadaMedia (6.7)0.45%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
ModificadaMedia (6.5)1.2%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or…
ModificadaAlta (8.8)1.7%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated…
ModificadaCrítica (9.8)6.4%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an…
ModificadaCrítica (9.8)1.9%—Ricoh D2200 FirmwareRicoh D5500 FirmwareRicoh D5510 FirmwareRicoh D5520 Firmware+49/1/201917/6/2026
SQL injection vulnerability in the RICOH Interactive Whiteboard D2200 V1.3 to V2.2, D5500 V1.3 to V2.2, D5510 V1.3 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.3 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard…
ModificadaMedia (5.9)0.50%—Ricoh D2200 FirmwareRicoh D5500 FirmwareRicoh D5510 FirmwareRicoh D5520 Firmware+49/1/201917/6/2026
The RICOH Interactive Whiteboard D2200 V1.3 to V2.2, D5500 V1.3 to V2.2, D5510 V1.3 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.3 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard Controller Type2 V3.0 to…
ModificadaAlta (8.8)0.60%—Ricoh D2200 FirmwareRicoh D5500 FirmwareRicoh D5510 FirmwareRicoh D5520 Firmware+49/1/201917/6/2026
RICOH Interactive Whiteboard D2200 V1.1 to V2.2, D5500 V1.1 to V2.2, D5510 V1.1 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.1 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard Controller Type2 V3.0 to V3.1.10137.0…
ModificadaAlta (7.8)0.98%—Ricoh D2200 FirmwareRicoh D5500 FirmwareRicoh D5510 FirmwareRicoh D5520 Firmware+49/1/201917/6/2026
RICOH Interactive Whiteboard D2200 V1.1 to V2.2, D5500 V1.1 to V2.2, D5510 V1.1 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.1 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard Controller Type2 V3.0 to V3.1.10137.0…
ModificadaCrítica (9.8)4.3%—Ricoh D2200 FirmwareRicoh D5500 FirmwareRicoh D5510 FirmwareRicoh D5520 Firmware+49/1/201917/6/2026
RICOH Interactive Whiteboard D2200 V1.6 to V2.2, D5500 V1.6 to V2.2, D5510 V1.6 to V2.2, and the display versions with RICOH Interactive Whiteboard Controller Type1 V1.6 to V2.2 attached (D5520, D6500, D6510, D7500, D8400) allows remote attackers to execute arbitrary commands via unspecified vectors.