CVE-2026-9397
A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Base score: 8.2
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.77%
- Percentile among all scored CVEs: 54
- Score date: 10/3/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1190Exploit Public-Facing Applicationinitial access72 % - Primary impact
T1068Exploitation for Privilege Escalationprivilege escalation65 %
Vector AV:N/PR:N/UI:N indica acceso remoto sin privilegios ni interacción (T1190). CWE-266/285 (improper authorization) en OTA Update Handler sugiere escalada de privilegios como impacto primario (T1068), aunque no se especifica qué comando/dato se accede post-explotación.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-266, CWE-285
References
Raw JSON (NVD)
Show
{
"id": "CVE-2026-9397",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-9397",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-05-26T14:37:09.452464Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 7.6,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "HIGH",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 4.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.2,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "PROOF_OF_CONCEPT",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"
],
"vendor": "Besen",
"modules": [
"OTA Update Installation Handler"
],
"product": "BS20 EV Charging Station",
"versions": [
{
"status": "affected",
"version": "20260426"
}
]
}
]
}
],
"published": "2026-05-24T21:16:32.767",
"references": [
{
"url": "https://github.com/carfeii/besen#finding-4-unauthorized-firmware-installation-via-spoofed-ota-updates",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/submit/813576",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/vuln/365378",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/vuln/365378/cti",
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-266"
},
{
"lang": "en",
"value": "CWE-285"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\""
},
{
"lang": "es",
"value": "Se ha identificado una debilidad en la estación de carga de vehículos eléctricos Besen BS20 hasta el 20260426. Este problema afecta a alguna funcionalidad desconocida del componente Gestor de instalación de actualizaciones OTA. Esta manipulación causa autorización indebida. El ataque puede ser llevado a cabo de forma remota. Se necesita un alto grado de complejidad para el ataque. Se sabe que la explotación es difícil. La divulgación original menciona que 'Estas vulnerabilidades han sido reportadas a Besen y hemos recibido su reconocimiento de que están revisando esto a partir de abril de 2026'."
}
],
"lastModified": "2026-07-23T11:10:00.120",
"sourceIdentifier": "cna@vuldb.com"
}