« Volver al listado

CVE-2026-92395

Estado: Pendiente de análisisCrítica (9.1)—

@fastify/proxy-addr is a Fastify plugin that determines a request's client address behind trusted reverse proxies, and it backs Fastify request.ip and request.ips. In versions 3.0.0 through 5.1.0, a trust subnet written in IPv4-mapped IPv6 notation with an IPv4-sized prefix, such as ::ffff:10.0.0.0/8 instead of the correct ::ffff:10.0.0.0/104, is accepted without error but trusts every IPv4 address on the internet rather than the block it names.

Leer descripción completaMostrar menos

Because the socket peer then becomes trusted at hop 0, any unauthenticated client can supply an arbitrary X-Forwarded-For header and control the address the application reads, which defeats IP-based access control, rate limiting, geolocation, and audit logging. The plugin inherited this defect from the upstream proxy-addr module (CVE-2026-90711). The issue is fixed in @fastify/proxy-addr 5.1.1, and users should upgrade to 5.1.1 or later. As a workaround, ensure any IPv4-mapped IPv6 trust subnet uses a prefix length of at least 97, or express the range in plain IPv4 notation.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vulnerabilidad en validación de subredes IPv6 (CWE-290) en plugin Fastify expuesto en red (AV:N, PR:N). Permitiendo falsificar X-Forwarded-For (T1078) y eludir controles de IP. Alto impacto de confidencialidad (C:H) sugiere acceso a datos sin autenticación. Afecta auditoría y geolocalización (T1005,

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-92395",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-92395",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-09-17T18:38:56.138579Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "ce714d77-add3-4f53-aff5-83d477b104bb",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ce714d77-add3-4f53-aff5-83d477b104bb",
      "affectedData": [
        {
          "vendor": "@fastify/proxy-addr",
          "product": "@fastify/proxy-addr",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0",
              "lessThan": "5.1.1",
              "versionType": "semver"
            },
            {
              "status": "unaffected",
              "version": "5.1.1",
              "versionType": "semver"
            }
          ],
          "packageURL": "pkg:npm/@fastify/proxy-addr",
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-09-16T15:19:01.857",
  "references": [
    {
      "url": "https://cna.openjsf.org/security-advisories.html",
      "source": "ce714d77-add3-4f53-aff5-83d477b104bb"
    },
    {
      "url": "https://github.com/fastify/proxy-addr/security/advisories/GHSA-8cmm-mhw6-v7xq",
      "source": "ce714d77-add3-4f53-aff5-83d477b104bb"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ce714d77-add3-4f53-aff5-83d477b104bb",
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        },
        {
          "lang": "en",
          "value": "CWE-348"
        },
        {
          "lang": "en",
          "value": "CWE-697"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "@fastify/proxy-addr is a Fastify plugin that determines a request's client address behind trusted reverse proxies, and it backs Fastify request.ip and request.ips. In versions 3.0.0 through 5.1.0, a trust subnet written in IPv4-mapped IPv6 notation with an IPv4-sized prefix, such as ::ffff:10.0.0.0/8 instead of the correct ::ffff:10.0.0.0/104, is accepted without error but trusts every IPv4 address on the internet rather than the block it names. Because the socket peer then becomes trusted at hop 0, any unauthenticated client can supply an arbitrary X-Forwarded-For header and control the address the application reads, which defeats IP-based access control, rate limiting, geolocation, and audit logging. The plugin inherited this defect from the upstream proxy-addr module (CVE-2026-90711). The issue is fixed in @fastify/proxy-addr 5.1.1, and users should upgrade to 5.1.1 or later. As a workaround, ensure any IPv4-mapped IPv6 trust subnet uses a prefix length of at least 97, or express the range in plain IPv4 notation."
    }
  ],
  "lastModified": "2026-09-17T19:17:07.053",
  "sourceIdentifier": "ce714d77-add3-4f53-aff5-83d477b104bb"
}