CVE-2026-89202
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.
CVSS
- Base score
- 7.1
- Version
- 4.0
- Vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days
- 0.37 %
- Percentile among all scored CVEs
- 29
- Score date
- 10/20/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1210Exploitation of Remote Serviceslateral movement85 % - Primary impact
T1499Endpoint Denial of Serviceimpact90 %
AV:N/PR:L sin UI:N indica acceso remoto autenticado; desconexión forzada de sesiones causa DoS. CWE-639 es fallo de autorización.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-639
References
Show 1 references
Raw JSON (NVD)
Show
{
"id": "CVE-2026-89202",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-89202",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-10-16T17:01:46.556256Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM CROSSBOW",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V6.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-10-13T10:17:21.790",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-639"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service."
}
],
"lastModified": "2026-10-16T18:19:42.823",
"sourceIdentifier": "productcert@siemens.com"
}