CVE-2026-89199
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.
CVSS
- Base score
- 8.7
- Version
- 4.0
- Vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days
- 0.34 %
- Percentile among all scored CVEs
- 26
- Score date
- 10/20/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1210Exploitation of Remote Serviceslateral movement85 % - Primary impact
T1552.007Container APIcredential access80 % - Secondary impact
T1068Exploitation for Privilege Escalationprivilege escalation70 % - Secondary impact
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access75 %
AV:N, PR:L sin UI indica acceso remoto con privilegios; consultas a BD para obtener credenciales admin (T1552.007); permite escalar privilegios (T1068) e impersonación de cuentas (T1078.001).
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-639
References
Show 1 references
Raw JSON (NVD)
Show
{
"id": "CVE-2026-89199",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-89199",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-10-13T15:49:43.544073Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM CROSSBOW",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V6.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-10-13T10:17:21.353",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-639"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation."
}
],
"lastModified": "2026-10-15T20:38:04.303",
"sourceIdentifier": "productcert@siemens.com"
}