« Back to list

CVE-2026-87426

Status: Undergoing AnalysisMedium (5.3)—

An unauthenticated network-based attacker can query specific internal management endpoints on Brocade ASCG versions before 3.5.0 to enumerate the configuration details and state of managed Brocade Fabric OS (FOS) switches. This results in the unauthorized disclosure of the customer's SAN fabric management topology and switch connectivity attributes.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

AV:A indica red adyacente sin autenticación; el acceso a endpoints de gestión para enumerar configuración de switches sin credenciales es explotación de servicio remoto (T1210). El impacto es lectura de datos sensibles: topología y atributos de conectividad (T1005).

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

Affected technologies (1)

⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2026-87426",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-87426",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-10-08T15:14:36.234352Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "sirt@brocade.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 5.3,
          "Automatable": "NOT_DEFINED",
          "attackVector": "ADJACENT",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "LOW",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "sirt@brocade.com",
      "affectedData": [
        {
          "vendor": "Brocade",
          "product": "Brocade Active Support Connectivity Gateway",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.0",
              "versionType": "Brocade ASC-G"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-10-08T07:16:33.270",
  "references": [
    {
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/38393",
      "source": "sirt@brocade.com"
    }
  ],
  "vulnStatus": "Undergoing Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "sirt@brocade.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthenticated network-based attacker can query specific internal management endpoints on Brocade ASCG versions before 3.5.0 to enumerate the configuration details and state of managed Brocade Fabric OS (FOS) switches. This results in the unauthorized disclosure of the customer's SAN fabric management topology and switch connectivity attributes."
    }
  ],
  "lastModified": "2026-10-08T20:08:45.857",
  "sourceIdentifier": "sirt@brocade.com"
}