CVE-2026-81574
In CodeMeter Runtime before versions 8.41a and 9.10, the logger does not sanitize input strings in certain cases, allowing an attacker to inject printf-style format specifiers. This can be used to reliably crash CodeMeter and disclose sensitive information such as process memory and stack canaries. The attack works locally, for example by using cmu --set-proxy to set the proxy value, and remotely when combined with CVE-2026-81573 by setting General.ProxyServer and then triggering this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
- Puntuación base: 8.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.43%
- Percentil entre todas las CVEs puntuadas: 35
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access75 % - Impacto principal
T1005Data from Local Systemcollection80 % - Impacto secundario
T1499.004Application or System Exploitationimpact85 %
Aplicación remota expuesta (AV:N, PR:N) con inyección de formato que causa lectura de memoria y DoS. La pista sugiere T1190; el ataque remoto (CVE-2026-81573) y acceso sin privilegios lo confirman.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-134
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-81574",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-81574",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-08-27T13:32:09.372443Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "2fc02b1f-71e7-4514-a878-169626f68903",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 4.2,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "2fc02b1f-71e7-4514-a878-169626f68903",
"affectedData": [
{
"vendor": "wibu-systems-ag",
"product": "codemeter-runtime",
"versions": [
{
"status": "affected",
"version": "9.00",
"lessThan": "9.10",
"versionType": "custom"
},
{
"status": "affected",
"version": "8.00",
"lessThan": "8.41a",
"versionType": "custom"
},
{
"status": "affected",
"version": "7.00"
},
{
"status": "unaffected",
"version": "6.00"
}
],
"collectionURL": "https://www.wibu.com/products/codemeter/runtime.html",
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-27T10:16:40.077",
"references": [
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-103401.pdf",
"source": "2fc02b1f-71e7-4514-a878-169626f68903"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "2fc02b1f-71e7-4514-a878-169626f68903",
"description": [
{
"lang": "en",
"value": "CWE-134"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In CodeMeter Runtime before versions 8.41a and 9.10, the logger does not sanitize input strings in certain cases, allowing an attacker to inject printf-style format\nspecifiers. This can be used to reliably crash CodeMeter and disclose sensitive information such as process memory\nand stack canaries. The attack works locally, for example by using cmu --set-proxy to set the proxy value, and\nremotely when combined with CVE-2026-81573 by setting General.ProxyServer and then triggering this\nvulnerability."
}
],
"lastModified": "2026-09-01T20:56:59.203",
"sourceIdentifier": "2fc02b1f-71e7-4514-a878-169626f68903"
}