Estado: Pendiente de análisisCrítica (9.1)—

A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-8066",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-8066",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-09-29T15:52:09.514722Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@hitachienergy.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@hitachienergy.com",
      "affectedData": [
        {
          "vendor": "Hitachi Energy",
          "product": "RTU500 series CMU firmware",
          "versions": [
            {
              "status": "affected",
              "version": "9.0",
              "lessThan": "12.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-09-29T10:17:13.250",
  "references": [
    {
      "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000251&LanguageCode=en&DocumentPartId=&Action=Launch",
      "source": "cybersecurity@hitachienergy.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@hitachienergy.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-23"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation."
    }
  ],
  "lastModified": "2026-09-29T21:39:02.570",
  "sourceIdentifier": "cybersecurity@hitachienergy.com"
}