CVE-2026-80149
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.58%
- Percentil entre todas las CVEs puntuadas: 46
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access92 % - Impacto principal
T1090Proxycommand and control95 % - Impacto secundario
T1526Cloud Service Discoverydiscovery78 %
SSRF en WebSSH sin autenticación (AV:N PR:N) explotable vía parámetro rooturl; permite redirigir conexiones SSH internas y reconocer la red. CWE-918 confirma SSRF. T1526 por capacidad de enumerar endpoints internos.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (4)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-918
Referencias
- https://revrb.net/2026/09/21/revrb-lantern.html
- https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/
- https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/
- https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/
- https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/
- https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-80149",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-80149",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-22T15:41:42.950532Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.6,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "LANTRONIX",
"product": "SLC8000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.7.0.3",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "LANTRONIX",
"product": "EMG8500",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.7.0.1",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "LANTRONIX",
"product": "EMG7500",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.7.0.1",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "LANTRONIX",
"product": "SLB882",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "LANTRONIX",
"product": "SLC9000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.7.0.2",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-22T16:18:01.160",
"references": [
{
"url": "https://revrb.net/2026/09/21/revrb-lantern.html",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-918"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
}
],
"lastModified": "2026-09-26T14:16:59.067",
"sourceIdentifier": "disclosure@vulncheck.com"
}