« Volver al listado

CVE-2026-80147

Estado: Pendiente de análisisCrítica (9.4)—

Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector AV:N + autenticación + ejecución arbitraria mediante buffer overflow en comando no documentado → T1210. El desbordamiento de pila permite ejecutar código (T1059), negar servicio (T1529) e infiltrar datos (T1565.001). CVSS indica impacto crítico en confidencialidad, integridad y disponibilidad

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (6)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-80147",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-80147",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-09-22T16:02:05.783698Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.9,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.1
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "LANTRONIX",
          "product": "SLC8000",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "9.7.0.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "LANTRONIX",
          "product": "EMG8500",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "9.7.0.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "LANTRONIX",
          "product": "EMG7500",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "9.7.0.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "LANTRONIX",
          "product": "SLB882",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "LANTRONIX",
          "product": "SLCx-03",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "LANTRONIX",
          "product": "SLCx-02",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "LANTRONIX",
          "product": "SLC9000",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "9.7.0.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-09-22T16:18:00.863",
  "references": [
    {
      "url": "https://revrb.net/2026/09/21/revrb-lantern.html",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write",
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
    }
  ],
  "lastModified": "2026-09-24T20:17:30.657",
  "sourceIdentifier": "disclosure@vulncheck.com"
}