CVE-2026-79551
Tenda Technology Co., Ltd NVR_4H CH3 v2.1 V27.5.58.6 was discovered to contain a hardcoded cryptographic key.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 7.5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.30%
- Percentile among all scored CVEs: 21
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1210Exploitation of Remote Serviceslateral movement65 % - Primary impact
T1078Valid Accountsstealth · persistence · privilege escalation · initial access75 % - Secondary impact
T1005Data from Local Systemcollection70 % - Secondary impact
T1552.001Credentials In Filescredential access80 %
AV:A (red adyacente) + clave criptográfica hardcodeada permite acceso no autorizado al NVR_4H; la clave facilita autenticación y exfiltración de datos grabados.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-321
References
Raw JSON (NVD)
Show
{
"id": "CVE-2026-79551",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-79551",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-09-22T15:30:42.754550Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2026-09-15T15:17:22.073",
"references": [
{
"url": "http://tenda.com",
"source": "cve@mitre.org"
},
{
"url": "https://github.com/snyi001/CVE-2026-79551-Tenda",
"source": "cve@mitre.org"
},
{
"url": "https://www.tendacn.com/material/show/805569838370885",
"source": "cve@mitre.org"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-321"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda Technology Co., Ltd NVR_4H CH3 v2.1 V27.5.58.6 was discovered to contain a hardcoded cryptographic key."
}
],
"lastModified": "2026-09-22T20:00:03.713",
"sourceIdentifier": "cve@mitre.org"
}