CVE-2026-79417
Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.26%
- Percentil entre todas las CVEs puntuadas: 16
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1499.004Application or System Exploitationimpact80 %
Explotación corregida por reglas (vector CVSS): era T1068
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-284, CWE-367
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-79417",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-79417",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-30T19:03:25.244669Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2026-09-29T20:17:26.870",
"references": [
{
"url": "https://connorjaydunn.github.io/blog/posts/argus-monitor-ldos-cve-2026-79417/",
"source": "cve@mitre.org"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-284"
},
{
"lang": "en",
"value": "CWE-367"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service."
}
],
"lastModified": "2026-09-30T21:17:15.657",
"sourceIdentifier": "cve@mitre.org"
}