CVE-2026-78541
A stored OS command injection vulnerability exists in the parent-control module of TP-Link Archer BE3600 V1. An authenticated adjacent attacker with administrative access may store a crafted profile name containing shell metacharacters, which is later processed unsafely during daily cloud report generation and may result in arbitrary command execution.
Successful exploitation may allow command execution on the affected device with potential impact to device confidentiality, integrity, and availability.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.28%
- Percentil entre todas las CVEs puntuadas: 83
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 %
Vulnerabilidad de inyección de comandos en módulo remoto (reporte en nube) que requiere acceso adyacente y autenticación administrativa. La ejecución de comandos arbitrarios es el impacto confirmado del CWE-78 explotado.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-78541",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-78541",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-24T00:00:00+00:00"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"affectedData": [
{
"vendor": "TP-Link Systems Inc.",
"modules": [
"parent-control"
],
"product": "Archer BE3600 v1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.2.6 Build 20260617",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-24T19:17:04.553",
"references": [
{
"url": "https://www.tp-link.com/en/support/download/archer-be3600/v1/#Firmware",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
},
{
"url": "https://www.tp-link.com/us/support/download/archer-be3600/v1.26/#Firmware",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
},
{
"url": "https://www.tp-link.com/us/support/faq/5264/",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stored OS\ncommand injection vulnerability exists in the parent-control module of TP-Link\nArcher BE3600 V1. An authenticated adjacent attacker with administrative access\nmay store a crafted profile name containing shell metacharacters, which is\nlater processed unsafely during daily cloud report generation and may result in\narbitrary command execution.\n\n\n\n\n\nSuccessful\nexploitation may allow command execution on the affected device with potential\nimpact to device confidentiality, integrity, and availability."
}
],
"lastModified": "2026-08-28T19:02:53.760",
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630"
}