CVE-2026-78482
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to command execution.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.49%
- Percentil entre todas las CVEs puntuadas: 84
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1005Data from Local Systemcollection75 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
Vector CVSS con AV:L (acceso local), PR:L (bajo privilegio), UI:N: escalada de privilegios clásica. CWE-89 (OS Command Injection) permite ejecución de comandos como impacto primario; secundarios: lectura de datos y manipulación de ficheros en el sistema comprometido.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-78482",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-78482",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-09T15:56:43.146000Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "security_alert@emc.com",
"affectedData": [
{
"vendor": "Dell",
"product": "Secure Connect Gateway 5.0 - Application",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "5.36.00.00 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Dell",
"product": "Secure Connect Gateway 5.0 - Appliance",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "5.36.00.16 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-09T15:17:08.763",
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-in/000503426/dsa-2026-382-security-update-for-dell-secure-connect-gateway-virtual-edition-multiple-vulnerabilities",
"tags": [
"Vendor Advisory"
],
"source": "security_alert@emc.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to command execution."
}
],
"lastModified": "2026-09-09T20:04:01.073",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:secure_connect_gateway:*:*:*:*:application:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7978D545-2FDA-4B19-B0A5-F87E87EE8A59",
"versionEndExcluding": "5.36.00.00"
},
{
"criteria": "cpe:2.3:a:dell:secure_connect_gateway:*:*:*:*:virtual:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D6766A93-993A-40A7-9766-F830A1AE4C80",
"versionEndExcluding": "5.36.00.16"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security_alert@emc.com"
}