« Back to list

CVE-2026-73165

Status: Awaiting AnalysisHigh (8.6)—

Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

CWE-78 OS command injection en interfaz web remota con autenticación previa (PR:H). Permite ejecución de comandos arbitrarios como root en dispositivo Advantech EKI-1242IEIMS.

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

Affected technologies (1)

⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2026-73165",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-73165",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-09-17T18:49:08.390546Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 8.6,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "prodsec@nozominetworks.com",
      "affectedData": [
        {
          "vendor": "Advantech",
          "product": "EKI-1242IEIMS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "1.06.01"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Advantech",
          "product": "EKI-1242EIMS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "1.06.01"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-09-16T13:18:04.693",
  "references": [
    {
      "url": "https://advcloudfiles.advantech.com/cms/5dafee28-ad53-4d07-a328-7896fcc24b6e/Security%20Advisory%20PDF%20File/SECURITY-ADVISORY----EKI-1242IEIMS-updated-20260904.pdf",
      "source": "prodsec@nozominetworks.com"
    },
    {
      "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2026-73165",
      "source": "prodsec@nozominetworks.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "prodsec@nozominetworks.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters."
    },
    {
      "lang": "es",
      "value": "Nozomi Networks Labs identificó una CWE-78: Neutralización Inadecuada de Elementos Especiales utilizados en un Comando del SO ('inyección de comandos del SO') vulnerabilidad en la interfaz de gestión web de Advantech EKI-1242IEIMS en la versión de firmware V1.06.01 que permite a un atacante remoto autenticado ejecutar comandos arbitrarios del SO como root a través de parámetros de solicitud manipulados."
    }
  ],
  "lastModified": "2026-09-23T11:10:00.187",
  "sourceIdentifier": "prodsec@nozominetworks.com"
}