CVE-2026-71908
Multiple DrayTek VigorAP models contain a command injection vulnerability in the mesh_start_speed_test function. The vulnerability is caused by insufficient sanitization of the meshdevice_index and meshdevice_ip fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.27%
- Percentil entre todas las CVEs puntuadas: 82
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation70 %
CWE-78 (command injection) en servicio remoto con PR:H confirma T1210. Ejecución de comandos arbitrarios con root (VC:H/VI:H/VA:H) = T1059 primario + escalada implícita en impacto T1068.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-71908",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-71908",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-26T15:56:55.494644Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.6,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 918R",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.11",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 960C",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.12",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 1060C",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.12",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 906",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.13",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 912C",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.15",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "DrayTek Corporation",
"product": "VigorAP 903",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.4.22",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-24T18:17:02.420",
"references": [
{
"url": "https://www.draytek.com/about/security-advisory/multiple-remote-code-execution-and-buffer-overflow-vulnerabilities-in-vigorap-series-august-2026/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/draytek-vigorap-multiple-models-os-command-injection-via-mesh-start-speed-test",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple DrayTek VigorAP models contain a command injection vulnerability in the mesh_start_speed_test function. The vulnerability is caused by insufficient sanitization of the meshdevice_index and meshdevice_ip fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface."
}
],
"lastModified": "2026-08-26T17:17:12.260",
"sourceIdentifier": "disclosure@vulncheck.com"
}