CVE-2026-67560
Bendix EC80 Brake ECU is vulnerable to a stack-based buffer overflow, which may allow an attacker to crash the ECU. A crafted payload can then be used to remotely execute arbitrary code or inject arbitrary CAN bus traffic. This could cause the loss of the ABS function, steering assist, speedometer, and shifting.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.33%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement80 % - Impacto principal
T1059Command and Scripting Interpreterexecution75 % - Impacto secundario
T1499.004Application or System Exploitationimpact70 %
AV:A (red adyacente) sin privilegios → T1210. El overflow permite ejecución de código arbitrario (T1059) y DoS del ECU por crash (T1499.004), afectando funciones críticas del vehículo.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-67560",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-67560",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-28T13:50:27.752340Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.7,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Bendix",
"product": "EC80ESP+ J1708",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP+ 6S/6M",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP+ PLC",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP+ 2nd CAN",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP+ Integrated TPMS",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP 6S/6M",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP PLC",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP 2nd CAN",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP CAN Gateway",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP 4S/4M",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Bendix",
"product": "EC80ESP PLC",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-28T00:18:08.150",
"references": [
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05",
"source": "ics-cert@hq.dhs.gov"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Bendix EC80 Brake ECU\n is vulnerable to a stack-based buffer overflow, which may allow an \nattacker to crash the ECU. A crafted payload can then be used to \nremotely execute arbitrary code or inject arbitrary CAN bus traffic. \nThis could cause the loss of the ABS function, steering assist, \nspeedometer, and shifting."
}
],
"lastModified": "2026-09-03T18:09:03.317",
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}