CVE-2026-67367
A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions < V3.1.13), SIMOVE Fleetmanager V3.2 (All versions < V3.2.4), SIMOVE Fleetmanager V3.3 (All versions < V3.3.2), SIMOVE Fleetmanager V4.0 (All versions < V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions < V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.11%
- Percentil entre todas las CVEs puntuadas: 65
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access95 % - Impacto principal
T1005Data from Local Systemcollection90 % - Impacto secundario
T1552Unsecured Credentialscredential access85 %
Vector AV:N/PR:N/UI:N indica acceso remoto sin privilegios ni interacción (T1190). CWE-23 de traversal permite leer archivos arbitrarios (T1005), incluyendo almacenes de credenciales y claves privadas (T1552).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-23
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-67367",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-67367",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-09T15:56:26.529587Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.6,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.2,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIMOVE Fleetmanager V3.1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.1.13",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOVE Fleetmanager V3.2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.4",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOVE Fleetmanager V3.3",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOVE Fleetmanager V4.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V4.0.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLANT V1.7",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLANT V2.2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLANT V3.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLANT V3.1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.1.4",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-09-08T09:18:20.577",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517424.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-23"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions < V3.1.13), SIMOVE Fleetmanager V3.2 (All versions < V3.2.4), SIMOVE Fleetmanager V3.3 (All versions < V3.3.2), SIMOVE Fleetmanager V4.0 (All versions < V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions < V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets."
}
],
"lastModified": "2026-09-09T16:17:03.757",
"sourceIdentifier": "productcert@siemens.com"
}