CVE-2026-6733
Impact: Undici's HTTP/1.1 client is vulnerable to response queue poisoning on reused keep-alive sockets. An attacker-controlled upstream server can inject an unsolicited HTTP/1.1 response onto an idle socket after a request completes. When the client dispatches the next request on that socket, it associates the injected response with the new request, causing responses to be delivered to the wrong requests.
This requires an attacker-controlled or compromised upstream HTTP/1.1 server and keep-alive connection reuse.
Patches: Upgrade to undici v6.26.0, v7.28.0 or v8.5.0.
Workarounds: Disable keep-alive connection reuse by setting keepAliveTimeout: 0 on the Client or Pool.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
- Puntuación base: 3.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.27%
- Percentil entre todas las CVEs puntuadas: 17
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-367
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-6733",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-6733",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-17T18:30:07.748616Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.7,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"affectedData": [
{
"vendor": "undici",
"product": "undici",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.26.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "6.26.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "7.0.0",
"lessThan": "7.28.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "7.28.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "8.0.0",
"lessThan": "8.5.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "8.5.0",
"versionType": "semver"
}
],
"packageURL": "pkg:npm/undici",
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-06-17T18:18:05.473",
"references": [
{
"url": "https://cna.openjsf.org/security-advisories.html",
"tags": [
"Vendor Advisory"
],
"source": "ce714d77-add3-4f53-aff5-83d477b104bb"
},
{
"url": "https://github.com/nodejs/undici/security/advisories/GHSA-35p6-xmwp-9g52",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "ce714d77-add3-4f53-aff5-83d477b104bb"
},
{
"url": "https://hackerone.com/reports/3582376",
"tags": [
"Issue Tracking"
],
"source": "ce714d77-add3-4f53-aff5-83d477b104bb"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"description": [
{
"lang": "en",
"value": "CWE-367"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Impact:\nUndici's HTTP/1.1 client is vulnerable to response queue poisoning on reused keep-alive sockets. An attacker-controlled upstream server can inject an unsolicited HTTP/1.1 response onto an idle socket after a request completes. When the client dispatches the next request on that socket, it associates the injected response with the new request, causing responses to be delivered to the wrong requests.\n\nThis requires an attacker-controlled or compromised upstream HTTP/1.1 server and keep-alive connection reuse.\n\nPatches:\nUpgrade to undici v6.26.0, v7.28.0 or v8.5.0.\n\nWorkarounds:\nDisable keep-alive connection reuse by setting keepAliveTimeout: 0 on the Client or Pool."
}
],
"lastModified": "2026-06-27T23:46:06.553",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nodejs:undici:*:*:*:*:*:node.js:*:*",
"vulnerable": true,
"matchCriteriaId": "632BE4D6-A743-4F05-9B3F-FE6A7B3E58D2",
"versionEndExcluding": "6.27.0"
},
{
"criteria": "cpe:2.3:a:nodejs:undici:*:*:*:*:*:node.js:*:*",
"vulnerable": true,
"matchCriteriaId": "0C34D757-BB16-4E28-95D8-7D3FAC851B69",
"versionEndExcluding": "7.28.0",
"versionStartIncluding": "7.0.0"
},
{
"criteria": "cpe:2.3:a:nodejs:undici:*:*:*:*:*:node.js:*:*",
"vulnerable": true,
"matchCriteriaId": "37F3655C-C7AE-4B13-A5EB-6FE0A9566124",
"versionEndExcluding": "8.5.0",
"versionStartIncluding": "8.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ce714d77-add3-4f53-aff5-83d477b104bb"
}