CVE-2026-5495
Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the processing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25720.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
Proteus requiere interacción del usuario (abrir archivo PDSPRJ malicioso) y resulta en ejecución de código arbitrario; CWE-787 (buffer overflow) con UI:R dicta T1203. T1059 es el impacto por RCE.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-5495",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-5495",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-04-13T16:17:17.862658Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Labcenter Electronics",
"product": "Proteus",
"versions": [
{
"status": "affected",
"version": "8.17 SP5"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-04-11T01:16:18.697",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-257/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the processing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25720."
}
],
"lastModified": "2026-06-17T10:59:07.383",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:labcenter:proteus:8.17:sp5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "02C6A9A8-9638-4E28-B3D4-5E16A9C36AB6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}