« Back to list

CVE-2026-5397

Status: Awaiting AnalysisHigh (7.8)—

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

AV:L, PR:L sin UI permite escalada local. CWE-427 + DLL en directorio = DLL Hijacking (T1574.007). Ejecución con privilegios de administrador tras startup del servicio (T1059).

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2026-5397",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-5397",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-04-15T13:46:38.260570Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.1
      }
    ]
  },
  "affected": [
    {
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
      "affectedData": [
        {
          "vendor": "OMRON SOCIAL SOLUTIONS CO., Ltd.",
          "product": "PowerAttendant Standard Edition",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2 or lower",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "Windows"
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-04-15T05:16:45.740",
  "references": [
    {
      "url": "https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
    },
    {
      "url": "https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.\n\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup."
    }
  ],
  "lastModified": "2026-06-17T10:58:57.633",
  "sourceIdentifier": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
}