« Volver al listado

CVE-2026-5131

Estado: Pendiente de análisisMedia (6.9)—

GREENmod uses named pipes for communication between plugins, the web portal, and the system service, but the access control lists for these pipes are configured incorrectly. This allows an attacker to communicate with the stream and upload any XML or JSON file, which will be processed by the named pipe with the privileges of the user under whose context the service is running. This allows for Server-Side Request Forgery to any Windows system on which the agent is installed and which provides communication via SMB or WebDav.

This issue was fixed in version 2.8.33.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-5131",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-5131",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-04-17T11:44:55.994641Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cvd@cert.pl",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.9,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "LOW",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "LOW",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "LOW",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cvd@cert.pl",
      "affectedData": [
        {
          "vendor": "Nomios Poland",
          "product": "GREENmod",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.8.33",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-04-17T11:16:11.000",
  "references": [
    {
      "url": "https://cert.pl/posts/2026/04/CVE-2026-5131",
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://www.nomios.pl/greenmod/",
      "source": "cvd@cert.pl"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cvd@cert.pl",
      "description": [
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "GREENmod uses named pipes for communication between plugins, the web portal, and the system service, but the access control lists for these pipes are configured incorrectly. This allows an attacker to communicate with the stream and upload any XML or JSON file, which will be processed by the named pipe with the privileges of the user under whose context the service is running. This allows for Server-Side Request Forgery to any Windows system on which the agent is installed and which provides communication via SMB or WebDav.\n\nThis issue was fixed in version 2.8.33."
    }
  ],
  "lastModified": "2026-06-17T10:58:29.353",
  "sourceIdentifier": "cvd@cert.pl"
}