CVE-2026-4272
Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.
This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
- Base score: 8.1
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.53%
- Percentile among all scored CVEs: 43
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1203Exploitation for Client Executionexecution75 % - Primary impact
T1059Command and Scripting Interpreterexecution80 % - Secondary impact
T1078Valid Accountsstealth · persistence · privilege escalation · initial access70 %
AV:N, UI:R indica explotación remota con interacción del usuario (emparejamiento Bluetooth). Permite ejecución remota de comandos sin autenticación (CWE-306), con acceso a credenciales/sesión del host.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-306
References
Raw JSON (NVD)
Show
{
"id": "CVE-2026-4272",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-4272",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-04-06T14:00:57.144252Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@honeywell.com",
"affectedData": [
{
"vendor": "Honeywell",
"product": "Barcode Scanners",
"versions": [
{
"status": "affected",
"version": "C1 Base(Ingenic x1000)",
"lessThan": "GK000432BAA",
"versionType": "custom"
},
{
"status": "affected",
"version": "D1 Base(Ingenic x1600)",
"lessThan": "HE000085BAA",
"versionType": "custom"
},
{
"status": "affected",
"version": "A1/B1 Base(IMX25)",
"lessThan": "BK000763BAA_BK000765BAA_CU000101BAA",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-04-05T22:16:01.697",
"references": [
{
"url": "https://https://nvd.nist.gov/vuln/detail/CVE-2026-4272",
"source": "psirt@honeywell.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\n\nThis vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability."
},
{
"lang": "es",
"value": "La vulnerabilidad 'Missing Authentication for Critical Function' en los escáneres portátiles Honeywell permite el abuso de autenticación. Este problema afecta a los escáneres portátiles: desde C1 Base (Ingenic x1000) anterior a GK000432BAA, desde D1 Base (Ingenic x1600) anterior a HE000085BAA, desde A1/B1 Base (IMX25) anterior a BK000763BAA_BK000765BAA_CU000101BAA.\n\nEsta vulnerabilidad podría permitir que un atacante remoto dentro del alcance de Bluetooth de la estación base del escáner tenga la capacidad de ejecutar comandos del sistema de forma remota en el host conectado a la estación base sin autenticación. A este problema se le ha asignado CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 y se ha calificado con una severidad de Alta. Honeywell recomienda encarecidamente que los usuarios actualicen a la última versión identificada para resolver la vulnerabilidad."
}
],
"lastModified": "2026-07-24T20:10:00.147",
"sourceIdentifier": "psirt@honeywell.com"
}