CVE-2026-42566
Meshtastic is an open source mesh networking solution. Prior to version 2.7.23.b246bcd, a single node advertising a User.long_name that contains a malformed character encoding can render other radios unusable over BLE when managed through the iOS app. The malformed name does not need to be maliciously crafted — it can arise from ordinary buffer truncation and has been observed occurring naturally in the wild. At least one code path could place a null terminator in the middle of a multibyte sequence, leaving a malformed User.long_name in the node database.
Leer descripción completaMostrar menos
The problem surfaced downstream: the iOS app enforced encoding validation and therefore cannot parse a node database once it contains a poisoned entry. This caused BLE sync to enter a fail/retry loop, resulting in loss of control over the affected device. For a typical user managing their radio with the iOS app, the device becomes effectively unusable until the poisoned node ages out of the on-device database, or unless they have an alternate management path (e.g., the Python CLI, which can be used to identify and remove the offending entries manually). Because the malformed name propagates through the mesh, the temporary presence of a single affected node can degrade BLE management for iOS users across a wide geographical area for an extended period. Less technical users have no straightforward recovery path. Starting in version 2.7.23.b246bcd, the firmware has added input sanitization and regression tests demonstrating recovery for already-poisoned devices. The apps have also taken steps to ensure more graceful handling of malformed encoding sequences as well.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.49%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access75 % - Impacto principal
T1499.004Application or System Exploitationimpact80 % - Impacto secundario
T1565.001Stored Data Manipulationimpact65 %
Vector AV:N/AC:L/PR:N permite explotación remota sin privilegios (T1190). Malformed encoding en User.long_name causa fallo/reintento en sincronización BLE, degradando control del dispositivo (T1499.004 DoS de recursos); propagación en malla afecta múltiples usuarios (T1565.001 manipulación de datos
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-20
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-42566",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-42566",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-07-21T14:53:28.643598Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security-advisories@github.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "security-advisories@github.com",
"affectedData": [
{
"vendor": "meshtastic",
"product": "firmware",
"versions": [
{
"status": "affected",
"version": "< 2.7.23.b246bcd"
}
]
}
]
}
],
"published": "2026-07-20T00:16:58.050",
"references": [
{
"url": "https://github.com/meshtastic/firmware/commit/2cc13a1132d94b66a9505e7f07ee2d3e83bd0c95",
"tags": [
"Patch"
],
"source": "security-advisories@github.com"
},
{
"url": "https://github.com/meshtastic/firmware/security/advisories/GHSA-7ph5-2mjv-69h8",
"tags": [
"Vendor Advisory"
],
"source": "security-advisories@github.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "security-advisories@github.com",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Meshtastic is an open source mesh networking solution. Prior to version 2.7.23.b246bcd, a single node advertising a User.long_name that contains a malformed character encoding can render other radios unusable over BLE when managed through the iOS app. The malformed name does not need to be maliciously crafted — it can arise from ordinary buffer truncation and has been observed occurring naturally in the wild. At least one code path could place a null terminator in the middle of a multibyte sequence, leaving a malformed User.long_name in the node database. The problem surfaced downstream: the iOS app enforced encoding validation and therefore cannot parse a node database once it contains a poisoned entry. This caused BLE sync to enter a fail/retry loop, resulting in loss of control over the affected device. For a typical user managing their radio with the iOS app, the device becomes effectively unusable until the poisoned node ages out of the on-device database, or unless they have an alternate management path (e.g., the Python CLI, which can be used to identify and remove the offending entries manually). Because the malformed name propagates through the mesh, the temporary presence of a single affected node can degrade BLE management for iOS users across a wide geographical area for an extended period. Less technical users have no straightforward recovery path. Starting in version 2.7.23.b246bcd, the firmware has added input sanitization and regression tests demonstrating recovery for already-poisoned devices. The apps have also taken steps to ensure more graceful handling of malformed encoding sequences as well."
}
],
"lastModified": "2026-08-18T18:10:42.750",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:meshtastic:meshtastic_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2040D50F-8708-4B64-8D94-6BCDE3FD6D9A",
"versionEndIncluding": "2.7.22"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security-advisories@github.com"
}