« Volver al listado

CVE-2026-41926

Estado: AplazadaCrítica (9.3)—

WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the firewall.cgi binary across five request handlers that apply insufficient input validation. Attackers can inject arbitrary shell commands through vulnerable parameters like websURLFilter, websHostFilter, portForward, singlePortForward, and ipportFilter using subshell syntax or unfiltered parameters, with payloads persisting in NVRAM and re-executing on every subsequent firewall.cgi request.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Red pública sin autenticación (AV:N/PR:N/UI:N). Inyección de comandos OS en parámetros CGI sin validación (CWE-78), permitiendo ejecución arbitraria de shell con persistencia en NVRAM.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-41926",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-41926",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-05-06T13:57:25.066761Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.3,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "Shenzhen Yipu Commercial and Trading Co., Ltd",
          "product": "WDR201A WiFi Extender",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.02.0"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-05-04T20:16:19.450",
  "references": [
    {
      "url": "https://mstreet97.github.io/security-research/iot/vulnerability-disclosure/ai-assisted-research/cybersecurity/cve/2026/05/04/Teaching_the_Machine_Where_to_Look.html",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.made-in-china.com/showroom/yeapook/#:~:text=Established%20in%202015.%2CDistrict%2C%20Shenzhen%2C%20Guangdong%2C%20China",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/wdr201a-wifi-extender-os-command-injection-via-firewall-cgi",
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the firewall.cgi binary across five request handlers that apply insufficient input validation. Attackers can inject arbitrary shell commands through vulnerable parameters like websURLFilter, websHostFilter, portForward, singlePortForward, and ipportFilter using subshell syntax or unfiltered parameters, with payloads persisting in NVRAM and re-executing on every subsequent firewall.cgi request."
    }
  ],
  "lastModified": "2026-06-17T10:47:12.513",
  "sourceIdentifier": "disclosure@vulncheck.com"
}