CVE-2026-41922
WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the wireless.cgi binary that allows unauthenticated remote attackers to execute arbitrary shell commands by injecting malicious input into the sz11gChannel or PIN POST parameters. Attackers can exploit unsanitized parameter handling in the set_wifi_basic and set_wifi_do_wps functions to achieve remote code execution without authentication.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 6.66%
- Percentil entre todas las CVEs puntuadas: 94
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access95 % - Impacto principal
T1059.004Unix Shellexecution90 %
Vector CVSS con AV:N/PR:N/UI:N permite explotación remota sin autenticación (T1190). CWE-78 y descripción explícita de inyección de comandos shell en parámetros POST no sanitizados permite ejecutar comandos arbitrarios (T1059.004).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-78
Referencias
- https://mstreet97.github.io/security-research/iot/vulnerability-disclosure/ai-assisted-research/cybersecurity/cve/2026/05/04/Teaching_the_Machine_Where_to_Look.html
- https://www.made-in-china.com/showroom/yeapook/#:~:text=Established%20in%202015.%2CDistrict%2C%20Shenzhen%2C%20Guangdong%2C%20China
- https://www.vulncheck.com/advisories/wdr201a-wifi-extender-os-command-injection-via-wireless-cgi
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-41922",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-41922",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-05-04T20:04:21.561256Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "Shenzhen Yipu Commercial and Trading Co., Ltd",
"product": "WDR201A WiFi Extender",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.02.0"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-05-04T20:16:18.860",
"references": [
{
"url": "https://mstreet97.github.io/security-research/iot/vulnerability-disclosure/ai-assisted-research/cybersecurity/cve/2026/05/04/Teaching_the_Machine_Where_to_Look.html",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.made-in-china.com/showroom/yeapook/#:~:text=Established%20in%202015.%2CDistrict%2C%20Shenzhen%2C%20Guangdong%2C%20China",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/wdr201a-wifi-extender-os-command-injection-via-wireless-cgi",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the wireless.cgi binary that allows unauthenticated remote attackers to execute arbitrary shell commands by injecting malicious input into the sz11gChannel or PIN POST parameters. Attackers can exploit unsanitized parameter handling in the set_wifi_basic and set_wifi_do_wps functions to achieve remote code execution without authentication."
}
],
"lastModified": "2026-06-17T10:47:12.093",
"sourceIdentifier": "disclosure@vulncheck.com"
}