CVE-2026-41918
Estado: AplazadaMedia (5.9)—
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V4.0). The affected applications stores sensitive information in the browser cache when an authenticated user modify specific configurations. This could allow an authenticated attacker to access sensitive data stored in the browser.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.33%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-525
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-41918",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-41918",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-02T14:13:46.231135Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.7,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.1
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM RST2428P",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V4.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-06-02T14:16:53.200",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-253495.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-525"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V4.0). The affected applications stores sensitive information in the browser cache when an authenticated user modify specific configurations. This could allow an authenticated attacker to access sensitive data stored in the browser."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en RUGGEDCOM RST2428P (6GK6242-6PA00) (Todas las versiones < V4.0). Las aplicaciones afectadas almacenan información sensible en la caché del navegador cuando un usuario autenticado modifica configuraciones específicas. Esto podría permitir a un atacante autenticado acceder a datos sensibles almacenados en el navegador."
}
],
"lastModified": "2026-07-22T19:10:00.120",
"sourceIdentifier": "productcert@siemens.com"
}