« Volver al listado

CVE-2026-36174

Estado: AplazadaMedia (4.6)—

GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-36174",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-36174",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-06-08T13:59:07.714870Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.6,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2026-06-04T15:16:51.093",
  "references": [
    {
      "url": "https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-256"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface."
    },
    {
      "lang": "es",
      "value": "Se descubrió que GNCC GP5 v7.1.76 almacenaba información sensible de la red inalámbrica en texto plano durante operaciones rutinarias en la consola serie. Este problema permite a atacantes físicamente próximos obtener información sensible, incluyendo credenciales de red, mediante la monitorización de la interfaz UART serie."
    }
  ],
  "lastModified": "2026-07-22T20:10:00.127",
  "sourceIdentifier": "cve@mitre.org"
}