« Back to list

CVE-2026-35073

Status: ModifiedMedium (6.7)—

Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2026-35073",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-35073",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-04-17T00:00:00+00:00"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerProtect Data Domain",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "8.7.0.1 or later",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "0",
              "lessThan": "8.3.1.30 or later",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "0",
              "lessThan": "7.13.1.70 or later",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-04-17T11:16:10.610",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000450699/dsa-2026-060-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an\nimproper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with\n root privileges."
    }
  ],
  "lastModified": "2026-08-04T09:16:36.543",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FC897776-0E86-478C-B120-1D5D89C2B488",
              "versionEndExcluding": "7.13.1.70",
              "versionStartIncluding": "7.7.1.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A28B7834-5B62-4CDE-B628-0BAC62AADD08",
              "versionEndExcluding": "8.3.1.30",
              "versionStartIncluding": "7.14.0.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1717B5B3-E190-4BE6-AAFC-CE0924D8497E",
              "versionEndIncluding": "8.6.1.10",
              "versionStartIncluding": "8.4.0.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:8.7.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "00FDFE5B-55C4-4045-8BAC-73047E3F36EC"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}