CVE-2026-33862
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.28%
- Percentil entre todas las CVEs puntuadas: 18
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1189Drive-by Compromiseinitial access85 % - Impacto principal
T1059.007JavaScriptexecution75 %
CWE-79 (XSS) en aplicación web Teamcenter con AV:N, AC:L, UI:P permite inyectar código malicioso ejecutado en navegador de otros usuarios (T1189). Ejecución de JavaScript en contexto del cliente (T1059.007).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-33862",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-33862",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-05-13T01:41:31.594862Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Teamcenter V2312",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2312.0014",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2406",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2406.0012",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2412",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2412.0009",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2506",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2506.0005",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2512",
"versions": [
{
"status": "unaffected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-05-12T10:16:45.773",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page."
}
],
"lastModified": "2026-06-17T10:38:13.427",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "502FFA43-E0FC-4415-A54B-880F2FA8B9B9",
"versionEndExcluding": "2312.0014",
"versionStartIncluding": "2312.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD39BCD3-7659-4CF7-945A-2379CB6EB292",
"versionEndExcluding": "2406.0012",
"versionStartIncluding": "2406.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9F592AE-C478-4EAE-B6E0-9DF1BA6B3CC9",
"versionEndExcluding": "2412.0009",
"versionStartIncluding": "2412.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "85FAC831-1B4B-4554-8FDC-970E37682EE9",
"versionEndExcluding": "2506.0005",
"versionStartIncluding": "2506.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}