Estado: AnalizadaMedia (5.1)—
SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a cross-site request forgery vulnerability in its management interface that allows attackers to induce authenticated users into submitting forged requests. Attackers can craft malicious requests that execute unauthorized configuration or administrative actions with the victim's privileges when the authenticated user visits a malicious webpage.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-352
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-27758",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-27758",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-02-27T18:56:26.183929Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks)",
"product": "SODOLA SL902-SWTGW124AS",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "200.1.20"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-02-27T19:16:10.183",
"references": [
{
"url": "https://www.sodola-network.com/products/sodola-6-port-2-5g-easy-web-managed-switch-4-x-2-5g-base-t-ports-2-x-10g-sfp-static-aggregation-qos-vlan-igmp-2-5gb-network-home-lab-switch",
"tags": [
"Product"
],
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/sodola-sl902-swtgw124as-missing-csrf-protections",
"tags": [
"Third Party Advisory"
],
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a cross-site request forgery vulnerability in its management interface that allows attackers to induce authenticated users into submitting forged requests. Attackers can craft malicious requests that execute unauthorized configuration or administrative actions with the victim's privileges when the authenticated user visits a malicious webpage."
},
{
"lang": "es",
"value": "Las versiones de firmware de SODOLA SL902-SWTGW124AS hasta la 200.1.20 contienen una vulnerabilidad de falsificación de petición en sitios cruzados en su interfaz de gestión que permite a los atacantes inducir a usuarios autenticados a enviar peticiones falsificadas. Los atacantes pueden elaborar peticiones maliciosas que ejecutan acciones de configuración o administración no autorizadas con los privilegios de la víctima cuando el usuario autenticado visita una página web maliciosa."
}
],
"lastModified": "2026-06-17T10:27:38.853",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sodola-network:sl902-swtgw124as_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "18BBB9A4-A6EC-45DD-955C-2070C0098E91",
"versionEndIncluding": "200.1.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sodola-network:sl902-swtgw124as:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "542ED775-5070-40DA-88A5-6FA98075BAD5"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "disclosure@vulncheck.com"
}