« Volver al listado

CVE-2026-27511

Estado: AnalizadaMedia (5.1)—

Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and trick an authenticated administrator into unintended interactions that may result in unauthorized configuration changes.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-27511",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-27511",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-02-23T18:38:40.099975Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 5.1,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "ACTIVE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "LOW",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "Shenzhen Tenda Technology Co., Ltd.",
          "product": "Tenda F3",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "12.01.01.55_multi"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2026-02-23T17:23:29.473",
  "references": [
    {
      "url": "https://www.tendacn.com/product/F3",
      "tags": [
        "Product"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/tenda-f3-clickjacking-in-web-management-interface",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1021"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and trick an authenticated administrator into unintended interactions that may result in unauthorized configuration changes."
    },
    {
      "lang": "es",
      "value": "El firmware V12.01.01.55_multi del router inalámbrico Shenzhen Tenda F3 contiene una vulnerabilidad de clickjacking en la interfaz de administración basada en web. La interfaz no establece el encabezado X-Frame-Options, lo que permite que sitios controlados por el atacante incrusten páginas de administración en un iframe y engañen a un administrador autenticado para que realice interacciones no intencionadas que pueden resultar en cambios de configuración no autorizados."
    }
  ],
  "lastModified": "2026-06-17T10:27:16.873",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f3_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C94698A5-D2EE-45CD-AB06-4BD30F252920",
              "versionEndIncluding": "12.01.01.55_multi"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f3:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EE9480BB-FC48-4614-A003-A991109FBCAF"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com"
}