CVE-2026-23855
Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.93%
- Percentil entre todas las CVEs puntuadas: 59
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement90 % - Impacto principal
T1059Command and Scripting Interpreterexecution95 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation75 %
AV:N/PR:H indica explotación remota con privilegios altos (T1210). CWE-78 y descripción explícita de 'command injection' confirman T1059. La escalada a root/admin en iDRAC es probable dado el contexto de gestión remota.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-23855",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-23855",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-09-10T00:00:00+00:00"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "security_alert@emc.com",
"affectedData": [
{
"vendor": "Dell",
"product": "iDRAC9",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "7.30.10.50 or later",
"versionType": "semver"
},
{
"status": "affected",
"version": "0",
"lessThan": "7.00.00.184 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Dell",
"product": "iDRAC10",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.30.30.50 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-09T17:17:19.837",
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000504998/dsa-2026-392-security-update-for-dell-idrac9-and-idrac10-vulnerability",
"source": "security_alert@emc.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Dell iDRAC9, 14G versions prior to 7.00.00.184, 15G/16G versions prior to 7.30.10.50, and Dell iDRAC10, 17G versions prior to 1.30.30.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command injection."
}
],
"lastModified": "2026-09-11T04:17:40.123",
"sourceIdentifier": "security_alert@emc.com"
}