« Volver al listado

CVE-2026-2273

Estado: AnalizadaAlta (7.2)—

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

CWE-94 (code injection) con AV:L, UI:A y usuario autenticado (PR:L) abriendo archivo malicioso es ejecución en cliente. T1059 por inyección de código; T1068 por pérdida de integridad del sistema posterior.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-2273",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-2273",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-03-10T17:42:09.226674Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.2,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.5
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.2,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "ACTIVE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "LOW",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "LOW",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "EcoStruxure™ Automation Expert",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to v25.0.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-03-10T18:18:48.007",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-04.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file."
    },
    {
      "lang": "es",
      "value": "CWE-94: Existe una vulnerabilidad de Control inadecuado de la generación de código ('Inyección de código') que podría causar la ejecución de comandos no confiables en la estación de trabajo de ingeniería, lo que podría resultar en un compromiso limitado de la estación de trabajo y una posible pérdida de Confidencialidad, Integridad y Disponibilidad del sistema subsiguiente cuando un usuario autenticado abre un archivo de proyecto malicioso."
    }
  ],
  "lastModified": "2026-06-23T13:53:23.937",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_automation_expert:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3175FEA8-B52B-4A9E-A51E-83C5F25B395C",
              "versionEndExcluding": "25.0.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}