CVE-2026-22540
The massive sending of ARP requests causes a denial of service on one board of the charger that allows control of the EV interfaces. Since the board must be operating correctly for the charger to also function correctly.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.37%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access75 % - Impacto principal
T1499.004Application or System Exploitationimpact85 %
Vector CVSS indica acceso remoto sin autenticación (AV:N/PR:N/UI:N). El ataque masivo de solicitudes ARP causa negación de servicio (CWE-400: Uncontrolled Resource Consumption). Explotación de servicio expuesto en tablero de cargador de vehículos eléctricos.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-400
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-22540",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-22540",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-01-07T14:31:51.301158Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "50b5080a-775f-442e-83b5-926b5ca517b6",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.2,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "50b5080a-775f-442e-83b5-926b5ca517b6",
"affectedData": [
{
"vendor": "EFACEC",
"product": "QC60/90/120",
"versions": [
{
"status": "affected",
"version": "8"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-07T15:15:46.703",
"references": [
{
"url": "https://cds.thalesgroup.com/en",
"source": "50b5080a-775f-442e-83b5-926b5ca517b6"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "50b5080a-775f-442e-83b5-926b5ca517b6",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The massive sending of ARP requests causes a denial of service on one board of the charger that allows control of the EV interfaces. Since the board must be operating correctly for the charger to also function correctly."
},
{
"lang": "es",
"value": "El envío masivo de solicitudes ARP causa una denegación de servicio en una placa del cargador que permite el control de las interfaces del VE. Dado que la placa debe estar funcionando correctamente para que el cargador también funcione correctamente."
}
],
"lastModified": "2026-06-17T10:20:03.230",
"sourceIdentifier": "50b5080a-775f-442e-83b5-926b5ca517b6"
}