« Volver al listado

CVE-2026-2250

Estado: AplazadaAlta (7.5)—

The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:N/PR:N/UI:N indica acceso remoto sin autenticación: T1190. El atacante accede a BD SQLite interna (T1005) y obtiene datos sensibles de configuración del sistema y rutas (T1552) mediante trazas de error en modo debug.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-2250",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-2250",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-02-11T15:00:06.523607Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
      "affectedData": [
        {
          "vendor": "METIS Cyberspace Technology SA",
          "product": "METIS WIC",
          "versions": [
            {
              "status": "affected",
              "version": "oscore 2.1.234-r18",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "oscore 2.1.235-r19",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-02-11T15:16:17.760",
  "references": [
    {
      "url": "https://cydome.io/vulnerability-advisory-cve-2026-2250-unauthenticated-data-exfilteration-and-information-disclosure-in-metis-wic-wireless-intelligent-collector",
      "source": "56a186b1-7f5e-4314-ba38-38d5499fccfd"
    },
    {
      "url": "https://www.metis.tech/",
      "source": "56a186b1-7f5e-4314-ba38-38d5499fccfd"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
      "description": [
        {
          "lang": "en",
          "value": "CWE-215"
        },
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration."
    },
    {
      "lang": "es",
      "value": "El endpoint web /dbviewer/ en dispositivos METIS WIC está expuesto sin autenticación. Un atacante remoto puede acceder y exportar la base de datos SQLite de telemetría interna que contiene datos operativos sensibles. Además, la aplicación está configurada con el modo de depuración habilitado, lo que hace que las solicitudes malformadas devuelvan rastreos de pila detallados de Django que revelan el código fuente del backend, las rutas de archivos locales y la configuración del sistema."
    }
  ],
  "lastModified": "2026-06-17T10:30:37.927",
  "sourceIdentifier": "56a186b1-7f5e-4314-ba38-38d5499fccfd"
}