« Volver al listado

CVE-2026-22270

Estado: AnalizadaMedia (6.7)—

Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an uncontrolled search path element vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service, elevation of privileges, and information disclosure.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-22270",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-22270",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-03-04T00:00:00+00:00"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerScale OneFS,",
          "versions": [
            {
              "status": "affected",
              "version": "9.11.0.0 through 9.12.0.1",
              "lessThan": "9.13.0.0 or later",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "prior to 9.10.1.6",
              "lessThan": "9.10.1.6 or later",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-03-04T13:15:57.967",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-sg/000432452/dsa-2026-038-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an uncontrolled search path element vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service, elevation of privileges, and information disclosure."
    },
    {
      "lang": "es",
      "value": "Dell PowerScale OneFS, versiones anteriores a 9.10.1.6 y versiones desde 9.11.0.0 hasta 9.12.0.1, contiene una vulnerabilidad de elemento de ruta de búsqueda no controlada. Un atacante con altos privilegios y acceso local podría potencialmente explotar esta vulnerabilidad, lo que podría llevar a una denegación de servicio, elevación de privilegios y revelación de información."
    }
  ],
  "lastModified": "2026-06-17T10:19:40.320",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C542DE7A-D4BD-4127-A14F-6A1D151A40F6",
              "versionEndExcluding": "9.10.1.6"
            },
            {
              "criteria": "cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "23042111-E6E9-4C6B-8A89-2E7E3F44103F",
              "versionEndExcluding": "9.13.0.0",
              "versionStartIncluding": "9.11.0.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}