CVE-2026-21635
Estado: AnalizadaMedia (6.5)—
An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-284
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-21635",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-21635",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-01-05T19:38:40.411282Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "support@hackerone.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.6
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "support@hackerone.com",
"affectedData": [
{
"vendor": "Ubiquiti Inc",
"product": "UniFi Connect EV Station Lite",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.6.1",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-05T17:15:47.350",
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-059/0c0b7f7a-68b7-41b9-987e-554f4b40e0e6",
"tags": [
"Vendor Advisory"
],
"source": "support@hackerone.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet."
},
{
"lang": "es",
"value": "Un control de acceso inadecuado podría permitir a un actor malicioso dentro del alcance de Wi-Fi de la EV Station Lite (v1.5.2 y anteriores) utilizar la función WiFi AutoLink en un dispositivo que solo fue adoptado a través de Ethernet."
}
],
"lastModified": "2026-06-17T10:18:50.967",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ui:unifi_connect_ev_station_lite_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D5EBEF9D-3DC1-47DB-A23B-F63D3B5F378B",
"versionEndExcluding": "1.6.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ui:unifi_connect_ev_station_lite:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9BD1ED22-51D2-485D-BF58-D9183AF27857"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "support@hackerone.com"
}