CVE-2026-20320
A vulnerability in the Open Client Interface (OCI) XML Parser of Cisco BroadWorks could allow an unauthenticated, remote attacker to read sensitive configuration information on an affected system.
This vulnerability exists because XML entries are improperly parsed due to external entity resolution being allowed by default. An attacker could exploit this vulnerability by sending a crafted XML message to the Open Client Interface – Provisioning (OCI-P) service. A successful exploit could allow the attacker to view sensitive files from the filesystem with the privileges of the Cisco BroadWorks user.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.50%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access90 % - Impacto principal
T1005Data from Local Systemcollection85 % - Impacto secundario
T1552Unsecured Credentialscredential access75 %
AV:N/PR:N/UI:N indica acceso remoto sin privilegios ni interacción (T1190). XXE permite leer ficheros del sistema (T1005) y potencialmente exponer datos sensibles de configuración (T1552).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-611
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-20320",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-20320",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-08-19T19:13:45.421692Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "psirt@cisco.com",
"affectedData": [
{
"vendor": "Cisco",
"product": "Cisco BroadWorks",
"versions": [
{
"status": "affected",
"version": "N/A"
}
]
}
]
}
],
"published": "2026-08-19T17:18:40.433",
"references": [
{
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-bworks-xxe-uwUd7CEt",
"source": "psirt@cisco.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-611"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Open Client Interface (OCI) XML Parser of Cisco BroadWorks could allow an unauthenticated, remote attacker to read sensitive configuration information on an affected system.\r\n\r This vulnerability exists because XML entries are improperly parsed due to external entity resolution being allowed by default. An attacker could exploit this vulnerability by sending a crafted XML message to the Open Client Interface – Provisioning (OCI-P) service. A successful exploit could allow the attacker to view sensitive files from the filesystem with the privileges of the Cisco BroadWorks user."
}
],
"lastModified": "2026-08-20T13:01:19.947",
"sourceIdentifier": "psirt@cisco.com"
}