« Volver al listado

CVE-2026-20177

Estado: Pendiente de análisisMedia (5.3)—

A vulnerability in the handling of management plane packets by Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an unauthenticated, remote attacker to cause the device manager, SSH, or API to become inaccessible.This vulnerability is due to insufficient protection against management plane flooding attacks. An attacker could exploit this vulnerability by sending a high rate of ICMP, SSH, or HTTP traffic to an affected device. A successful exploit could allow the attacker to cause the CPU of the device to increase, resulting in a denial of service (DoS) condition on the device manager web GUI, SSH, or API. Data traffic through the device is not affected.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-20177",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-20177",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-08-20T15:39:52.842587Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@cisco.com",
      "affectedData": [
        {
          "vendor": "Cisco",
          "product": "Cisco Industrial Ethernet Switches",
          "versions": [
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "1.2"
            },
            {
              "status": "affected",
              "version": "1.8.0"
            },
            {
              "status": "affected",
              "version": "1.8.2"
            },
            {
              "status": "affected",
              "version": "1.7.0"
            },
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.9.1"
            },
            {
              "status": "affected",
              "version": "1.6"
            },
            {
              "status": "affected",
              "version": "1.8.1"
            },
            {
              "status": "affected",
              "version": "1.9.2"
            },
            {
              "status": "affected",
              "version": "1.9.2a"
            },
            {
              "status": "affected",
              "version": "1.9.3"
            },
            {
              "status": "affected",
              "version": "1.9.4"
            },
            {
              "status": "affected",
              "version": "1.9.5"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2026-08-19T17:18:39.093",
  "references": [
    {
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ie1k-uxq86Lnx",
      "source": "psirt@cisco.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the handling of management plane packets by Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an unauthenticated, remote attacker to cause the device manager, SSH, or API to become inaccessible.This vulnerability is due to insufficient protection against management plane flooding attacks. An attacker could exploit this vulnerability by sending a high rate of ICMP, SSH, or HTTP traffic to an affected device. A successful exploit could allow the attacker to cause the CPU of the device to increase, resulting in a denial of service (DoS) condition on the device manager web GUI, SSH, or API. Data traffic through the device is not affected."
    }
  ],
  "lastModified": "2026-08-20T16:17:20.400",
  "sourceIdentifier": "psirt@cisco.com"
}