CVE-2026-17583
The affected
Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.14%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation75 % - Impacto principal
T1565.001Stored Data Manipulationimpact80 % - Impacto secundario
T1657Financial Theftimpact70 %
Acceso local sin interacción (AV:L, PR:N, UI:N) con integridad alta (VI:H) permite escalada o manipulación de archivos .fsa/.hid. CWE-353 (temporal race condition) facilita edición maliciosa de datos de ADN, alterando resultados de pruebas genéticas.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (8)
CWE
- CWE-353
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-17583",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-17583",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-06T13:34:47.788856Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.4,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.5
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems 3500/3500xL Series Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "4.0.2"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems 3730/3730xL Series Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "5.0.2"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.2.5"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems SeqStudio Flex Series Instrument Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.2.0"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems GeneMapper ID-X Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.7.3"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "Applied Biosystems 3130 Series Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "4.1"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "ABI PRISM 3100/3100-Avant Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2.0"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Thermo Fisher",
"product": "ABI PRISM 310 Data Collection Software",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "3.1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-05T21:16:57.393",
"references": [
{
"url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cve.org/CVERecord?id=CVE-2026-17583",
"tags": [
"Third Party Advisory"
],
"source": "ics-cert@hq.dhs.gov"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-353"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected\n\nThermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes."
}
],
"lastModified": "2026-08-26T14:50:43.400",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:thermofisher:abi_prism_310_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "052676E2-92C8-480C-B163-D3C4AEBA6ECF",
"versionEndIncluding": "3.1"
},
{
"criteria": "cpe:2.3:a:thermofisher:abi_prism_3100\\/3100-avant_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "24B89BAB-EFA0-48D1-9E12-621A3AD95438",
"versionEndIncluding": "2.0"
},
{
"criteria": "cpe:2.3:a:thermofisher:applied_biosystems_3130_series_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2DA06A19-0C69-43AC-91C4-CBCCEB3E1525",
"versionEndIncluding": "4.1"
},
{
"criteria": "cpe:2.3:a:thermofisher:applied_biosystems_3500\\/3500xl_series_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A594FA04-80D2-44F5-B0E3-BB8A9600D68A",
"versionEndExcluding": "4.0.3"
},
{
"criteria": "cpe:2.3:a:thermofisher:applied_biosystems_3730\\/3730xl_series_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "946E2337-8B1B-49F4-9597-A38C1CCC7A30",
"versionEndExcluding": "5.0.3"
},
{
"criteria": "cpe:2.3:a:thermofisher:applied_biosystems_seqstudio_flex_series_instrument_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4A8182F-41FD-4271-9120-844764414F85",
"versionEndExcluding": "1.2.1"
},
{
"criteria": "cpe:2.3:a:thermofisher:applied_biosystems_seqstudio_genetic_analyzer_data_collection_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C85423A-B2C6-4D68-8B0A-394B5E8DB3AA",
"versionEndExcluding": "1.2.6"
},
{
"criteria": "cpe:2.3:a:thermofisher:genemapper_id-x:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E32BD188-9C4D-428D-8C64-154709AFE4AA",
"versionEndExcluding": "1.7.4"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}