CVE-2026-16835
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9.6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.36%
- Percentil entre todas las CVEs puntuadas: 28
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement90 % - Impacto principal
T1557Adversary-in-the-Middlecredential access · collection75 % - Impacto secundario
T1005Data from Local Systemcollection70 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation85 %
AV:A (red adyacente) sin autenticación requiere T1210. El bypass de autenticación en red de gestión permite suplantación (T1557), escalada a administrador (T1068) y acceso a datos de particiones (T1005).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (9)
CWE
- CWE-295
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-16835",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-16835",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-21T00:00:00+00:00"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.6,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@us.ibm.com",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"vendor": "IBM",
"product": "Power Systems Firmware",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"status": "affected",
"version": "FW1110.00",
"versionType": "semver",
"lessThanOrEqual": "FW1110.30"
},
{
"status": "affected",
"version": "FW1060.00",
"versionType": "semver",
"lessThanOrEqual": "FW1060.80"
},
{
"status": "affected",
"version": "FW950.00",
"versionType": "semver",
"lessThanOrEqual": "FW950.H2"
}
]
}
]
}
],
"published": "2026-08-19T19:17:10.690",
"references": [
{
"url": "https://www.ibm.com/support/pages/node/7283894",
"tags": [
"Vendor Advisory"
],
"source": "psirt@us.ibm.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system."
}
],
"lastModified": "2026-08-25T17:59:13.683",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1080_\\(9080-hex\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AA6D803F-DD5C-49A7-BE93-68981C124C69",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1080_\\(9080-hex\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DF85251B-E02C-4293-98F0-D331BF51CAC4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E8049F52-227B-4CCA-B059-5821F9B41C95",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00"
},
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F518B3DD-3F25-4581-9103-6CD4D8DA54C7"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1180_\\(9080-heu\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8BD4FC49-8120-4D4B-906A-1B6FA6B30FA2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s922_\\(9009-22g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0C406C5A-454C-4454-861F-80E629B68418",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s922_\\(9009-22g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "95E5E77F-A5BB-46E7-B6B6-B02F242DE829"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h922_\\(9223-22s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FBE7D8B3-902D-4CD1-9F31-454E293A79B3",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h922_\\(9223-22s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E7851003-8D6B-4FE8-87D7-BE968E85E448"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s914_\\(9009-41g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CD77C09F-AF62-4CD8-B64C-CDF50D696648",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s914_\\(9009-41g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "003F591A-ACCD-497E-BF8A-DE090321D778"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s924_\\(9009-42g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "54831AF9-D748-4649-A0ED-896341845BCD",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s924_\\(9009-42g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4038C5DB-DF9C-4661-9590-F6A0CD4D15D5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h924_\\(9223-42s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "64FD3222-EEFD-4533-A088-B05F04E0831D",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h924_\\(9223-42s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C2F0E93A-26F0-4914-8A31-3C86E64D5B8A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e950_\\(9040-mr9\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C99CF91B-A98D-4795-A8AE-998713989ABE",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e950_\\(9040-mr9\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9FF58E5C-0A54-4F2F-A426-0BFD1EACE991"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e980_\\(9080-m9s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "272B1267-28AC-4BDB-93C4-9804DBE240E0",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e980_\\(9080-m9s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9BE56BD8-DB0F-4151-9428-42F1B6452D99"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@us.ibm.com"
}