CVE-2026-16832
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.32%
- Percentil entre todas las CVEs puntuadas: 23
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement92 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation85 %
AV:A y PR:H indican acceso de red adyacente con privilegios elevados (admin HMC); ejecución de código arbitrario en el procesador de servicios con control total del sistema (confidencialidad, integridad, disponibilidad comprometidas).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (9)
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-16832",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-16832",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-21T00:00:00+00:00"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.4,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "psirt@us.ibm.com",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"vendor": "IBM",
"product": "Power Systems Firmware",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"status": "affected",
"version": "FW1110.00",
"versionType": "semver",
"lessThanOrEqual": "FW1110.30"
},
{
"status": "affected",
"version": "FW1060.00",
"versionType": "semver",
"lessThanOrEqual": "FW1060.80"
},
{
"status": "affected",
"version": "FW950.00",
"versionType": "semver",
"lessThanOrEqual": "FW950.H2"
}
]
}
]
}
],
"published": "2026-08-19T19:17:10.557",
"references": [
{
"url": "https://www.ibm.com/support/pages/node/7283895",
"tags": [
"Vendor Advisory"
],
"source": "psirt@us.ibm.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact."
}
],
"lastModified": "2026-08-25T18:04:01.390",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1080_\\(9080-hex\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AA6D803F-DD5C-49A7-BE93-68981C124C69",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1080_\\(9080-hex\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DF85251B-E02C-4293-98F0-D331BF51CAC4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E8049F52-227B-4CCA-B059-5821F9B41C95",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00"
},
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F518B3DD-3F25-4581-9103-6CD4D8DA54C7"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1180_\\(9080-heu\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8BD4FC49-8120-4D4B-906A-1B6FA6B30FA2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s922_\\(9009-22g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0C406C5A-454C-4454-861F-80E629B68418",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s922_\\(9009-22g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "95E5E77F-A5BB-46E7-B6B6-B02F242DE829"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h922_\\(9223-22s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FBE7D8B3-902D-4CD1-9F31-454E293A79B3",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h922_\\(9223-22s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E7851003-8D6B-4FE8-87D7-BE968E85E448"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s914_\\(9009-41g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CD77C09F-AF62-4CD8-B64C-CDF50D696648",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s914_\\(9009-41g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "003F591A-ACCD-497E-BF8A-DE090321D778"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s924_\\(9009-42g\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "54831AF9-D748-4649-A0ED-896341845BCD",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s924_\\(9009-42g\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4038C5DB-DF9C-4661-9590-F6A0CD4D15D5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h924_\\(9223-42s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "64FD3222-EEFD-4533-A088-B05F04E0831D",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h924_\\(9223-42s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C2F0E93A-26F0-4914-8A31-3C86E64D5B8A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e950_\\(9040-mr9\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C99CF91B-A98D-4795-A8AE-998713989ABE",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e950_\\(9040-mr9\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9FF58E5C-0A54-4F2F-A426-0BFD1EACE991"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e980_\\(9080-m9s\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "272B1267-28AC-4BDB-93C4-9804DBE240E0",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e980_\\(9080-m9s\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9BE56BD8-DB0F-4151-9428-42F1B6452D99"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@us.ibm.com"
}