CVE-2026-13248
An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows an authenticated user with access to the admin or itadmin account to submit commands written in the Intermec Fingerprint programming language directly to the printer ’s internal command interpreter.
An attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.44%
- Percentil entre todas las CVEs puntuadas: 36
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1078Valid Accountsstealth · persistence · privilege escalation · initial access75 % - Impacto secundario
T1505.003Web Shellpersistence80 %
Autenticación requerida (PR:L) en interfaz web remota permite ejecución de código e inyección de comandos Intermec; impacto de confidencialidad, integridad y disponibilidad (C:H/I:H/A:H) confirmado.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-73, CWE-78, CWE-434
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-13248",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-13248",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-09-24T19:19:35.275464Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@honeywell.com",
"affectedData": [
{
"vendor": "Honeywell",
"product": "PD45 Industrial Printer",
"versions": [
{
"status": "affected",
"version": "F10.19.010040",
"lessThan": "F10.22.030745",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-24T19:17:12.917",
"references": [
{
"url": "https://www.honeywell.com/us/en/legal/product-security#security-notices",
"source": "psirt@honeywell.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"description": [
{
"lang": "en",
"value": "CWE-73"
},
{
"lang": "en",
"value": "CWE-78"
},
{
"lang": "en",
"value": "CWE-434"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows an authenticated user with access to the admin or itadmin account to submit commands written in the Intermec Fingerprint programming language directly to the printer ’s internal command interpreter. \n\n\nAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability."
}
],
"lastModified": "2026-09-24T20:43:32.537",
"sourceIdentifier": "psirt@honeywell.com"
}