« Volver al listado

CVE-2026-12661

Estado: Pendiente de análisisMedia (4.8)—

A denial-of-service security issue exists within FactoryTalk® Historian Machine Edition.  A network adjacent attacker who is authenticated could send crafted requests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-12661",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-12661",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-09-01T15:48:47.860540Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 4.8,
          "Automatable": "NOT_DEFINED",
          "attackVector": "ADJACENT",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "LOW",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "FactoryTalk® Historian Machine Edition",
          "versions": [
            {
              "status": "affected",
              "version": "Series C: 7.101  Series B: 5.202"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-09-01T14:17:24.133",
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1796.html",
      "source": "PSIRT@rockwellautomation.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT@rockwellautomation.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A denial-of-service security issue exists within FactoryTalk® Historian Machine Edition.  A network adjacent attacker who is authenticated could send crafted requests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive."
    }
  ],
  "lastModified": "2026-09-01T20:50:01.960",
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}